We will be closed on Monday, May 27th 2024, in observance of Memorial Day. We will resume normal business hours on Tuesday, May 28th 2024.

Landtec GEM 5000 Plus Landfill Gas Monitor Rental

  • Measures methane (0-100%), carbon dioxide (0-100%), oxygen (0-25%), carbon monoxide (0-2000ppm), hydrogen sulfide (0-500ppm), static pressure and differential pressure
  • Calculates balance gas, flow (SCFM) and calorific value (KW or BTU)
  • High Accuracy and Fast Response Time
  • Certified intrinsically safe for landfill use
SKU
RN-LND-GEM5KPLS
Rental Rates
Daily Weekly Monthly
$208.00 $597.00 $1,546.00

The GEM™5000 is designed specifically for use on landfills to monitor Landfill Gas (LFG) Collection & Control Systems. The GEM™5000 samples and analyzes the methane, carbon dioxide and oxygen content of landfill gas with options for additional analysis.

The GEM5000 measures flow and calculates the calorific values of the gas as well as being a useful tool for balancing the gas field. The GEM5000 gas analyzer may be used to monitor, calculate, adjust and record the flow at each monitoring point. This instrument may also be used in GA (gas analyzer) mode of operation if required. The operator may change the analyzer between a gas extraction monitor (GEM mode) or a landfill gas analyzer (GA Mode).

Sensor Range
Methane 0 - 100%
Carbon Dioxide 0 - 100%
Oxygen 0 - 25%
Carbon Monoxide 0 - 2000 ppm
Hydrogen Sulfide 0 - 500 ppm
Detection Principle
  • CO2 and CH4 by dual wavelength infrared cell with reference channel.
  • O2, CO, and H2S by internal electrochemical cell.
Accuracy      
CH4 0-5% ± 0.3% (vol) 0-70% ± 0.5% (vol) 70-100% ± 1.5% FS
CO2 0-5% ± 0.3% (vol) 0-60% ± 0.5% (vol) 60-100% ± 1.5% FS
O2 0-25% ± 1.0% (vol)    
CO 0-2000ppm ± 1.0% FS    
H2S 0-500ppm ± 2.0% FS    
Other Parameters Unit Resolution Comments
Energy BTU/hr 1000 BTU/hr Calculated from specific parameters
Static Pressure in. H2O 0.1 in. H2O Direct Measurement
Differential Pressure in. H2O 0.001 in. H2O Direct Measurement
Sampling Pump Flow Typically 550 cc/min
Flow w/ 80 In. H2O vacuum Approx. 80 cc/min
Battery life Typical use 8 hours from fully charged
Charge time Approximately 3 hours from complete discharge.
Operating Temperature Range 14°F - 122°F (-10°C to +50°C)
Operating Pressure -100 In. H2O, +100 in. H2O (-250mbar, +250mbar)
Relative Humidity 0-95% non condensing
Barometric Pressure ± 14.7 in.Hg (±500mbar) from calibration pressure
Barometric Pressure Accuracy ± 1% typically
ATEX II 2G Ex ib IIA T1 Gb (Ta= -10°C to +50°C)
ISO17025 ISO/IEC17025:2005 Accreditation #66916
CSA Ex ib IIA T1 (Ta= -10°C to +50°C) (Canada), 
AEx ib IIA T1 (Ta= -10°C to +50°C) USA
  • GEM 5000
  • Data Cable
  • PVC Tubing
  • Hard Carrying Case
  • Soft Case with Strap
  • Instruction Manual
  • Water Trap Filter with Tubing
  • Battery Charger
  • LANDTEC System Gas Analyzer Manager Software
  • Field Calibration Record
  • Factory Calibration Certificate
  • Spare Filter